Both members are working on the final report and are updating their progress on lab archives. MH tested the algorithm on 20+ alginate bead images and found an 18 gauge needle with 0.6 bar N2 pressure produces better bead homogeneity than other bead-making methods. BG is working on the design safe analysis. Both members will verify/validate the prototype in the client’s lab tomorrow afternoon.